eZ80F92 Development Kit
User Manual
eZ80Acclaim!
®
Development Platform UM013911-0607
14
16 GND
17 A2 Bidirectional Yes
18 A1 Bidirectional Yes
19 A11 Bidirectional Yes
20 A12 Bidirectional Yes
21 A4 Bidirectional Yes
22 A20 Bidirectional Yes
23 A5 Bidirectional Yes
24 A17 Bidirectional Yes
25 DIS_ETH
Output Low No
26 EN_FLASH
Output Low No
27 A21 Bidirectional Yes
28 V
DD
29 A22 Bidirectional Yes
30 A23 Bidirectional Yes
Table 2. eZ80Acclaim!
®
Development Platform
Peripheral Bus Connector Identification—JP1* (Continued)
Pin # Symbol Signal Direction Active Level eZ80F92 Signal
2
Notes:
1. For the sake of simplicity in describing the interface, Power and Ground nets are omitted from
this table. The entire interface is represented in the eZ80F92 Module Schematics on pages 65
through 67.
2. The Power and Ground nets are connected directly to the eZ80F92 device.
3. External capacitive loads on RD
, WR, IORQ, MREQ, D0–D7 and A0–A23 should be below 10 pF
to satisfy the timing requirements for the eZ80
®
CPU. All unused inputs should be pulled to
either V
DD
or GND, depending on their inactive levels to reduce power consumption and to
reduce noise sensitivity. To prevent EMI, the EZ80CLK output can be deactivated via software in
the eZ80F92’s Peripheral Power-Down Register.