Zilog EZ80L92 Uživatelský manuál Strana 19

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 86
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 18
eZ80L92 Development Kit
User Manual
UM012913-0407 Operational Description
15
46 RD Bidirectional Low Yes
47 WR
Bidirectional Low Yes
48 INSTRD
Input Low Yes
49 BUSACK
Input Pull-Up 10 K; Low Yes
50 BUSREQ
Output Pull-Up 10 K; Low Yes
Table 2. eZ80Acclaim!
®
Development Platform Peripheral Bus Connector
Identification—JP1
1
(Continued)
Pin No. Symbol Signal Direction Active Level eZ80L92 Signal
2
Notes:
1. For the sake of simplicity in describing the interface, Power and Ground nets are omitted from
this table. The entire interface is represented in the eZ80L92 Module Schematics. see
eZ80L92 Module.
2. The Power and Ground nets are connected directly to the eZ80L92 device.
Additional note: external capacitive loads on RD
, WR, IORQ, MREQ, D0–D7 and A0–A23 should be
below 10 pF to satisfy the timing requirements for the eZ80
®
CPU. All unused inputs should be
pulled to either V
DD
or GND, depending on their inactive levels to reduce power consumption and
to reduce noise sensitivity. To prevent EMI, the EZ80CLK output can be deactivated via software in
the eZ80L92’s Peripheral Power-Down Register.
Zobrazit stránku 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 85 86

Komentáře k této Příručce

Žádné komentáře