Z8
®
CPU
User Manual
UM001604-0108 Instruction Description
246
Example 1
If Working Register R3 contains 45h (01000101b) and Working Register R7 contains the
value
02h (00000010b) (bit 1 is being tested if it is 0), the statement:
TM R3, R7
Op Code: 72 37
sets the Z Flag indicating bit 1 in the destination operand is 0. The V and S Flags are
cleared.
Example 2
Working Register R14 contains the value F3h (11110011b), Working Register R5 con-
tains
CBh, and Register CBh contains 88h (10001000b) (bit 7 a bit 3 are being tested if
they are 0), the statement:
TM R14, @R5
Op Code: 73 E5
resets the Z Flag, because bit 7 in the destination operand is not a 0. The S Flag is set, and
the V Flag is cleared.
Example 3
If Register D4h contains the value 08h (00001000b), and Working Register R0 contains
the value
04h (00000100b) (bit 2 is being tested if it is 0), the statement:
TM D4h, R0
Op Code: 74 E0 D4
sets the Z Flag, because bit 2 in the destination operand is a 0. The S and V Flags is
cleared.
Example 4
If Register DFh contains the value (00000000b), Register 07h contains the value 1Fh,
and Register
1Fh contains the value BDh (10111101b) (bit 7, bit 5, bit 4, bit 3, bit 2, and
bit 0 are being tested if they are 0), the statement:
TM DFh, @07h
Op Code: 75 07 DF
sets the Z Flag indicating the tested bits in the destination operand are 0. The S is set, and
the V Flag is cleared.
Example 5
If Working Register R13 contains the value F1h (11110001b), the statement:
TM R13, #02h
Op Code: 76 ED, 02